Sterility testing of disposable syringes and needles marketed in Calcutta.
D Pal, UK Chattopadhyay
Deptt. of Microbiology, All India Institute of Hygene & Public Health, Calcutta
Correspondence Address:
D Pal Deptt. of Microbiology, All India Institute of Hygene & Public Health, Calcutta
 Source of Support: None, Conflict of Interest: None  | Check |
PMID: 10389526 
|
|
Presterilized (disposable) syringes and needles were subjected to sterility testing for aerobic cultures. It was found that 56.3% of the samples were contaminated indicating failure of the sterilisation process. The implications of this could be far reaching and is discussed alongwith. |
|
|
|